Stock code:002309
Wechat Num:
SZ002309

Summary

New energy is a national key development direction, mainly for nuclear power, wind energy, solar energy use, each country\\\'s project to promote in in full swing, especially the use of new energy sources such as wind power and solar energy is the key point of the development of the countries in the future.

Advantages for the use of new energy development in the following cable: photovoltaic cable, wind cable, medium voltage cable accessory products, etc.

Product and description

  • Pv cable
    More...

    Range of application

    Widely used in solar power station, power transmission in the photovoltaic system, solar panels used for connection, battery or other collector unit.

    Execution standard

    IEC61215, TUV, UL4703 2 PFG - 2007

    Technical characteristics

    Photovoltaic system using advanced irradiation crosslinking process special wire and cable, low smoke zero halogen flame retardant materials production lines, it has high temperature resistance, ozone resistance, uv resistance, resistance to water vapor, antimicrobial, short-time overload ability, long service life, wear-resisting, oil, anti-corrosion, high tensile resistance, etc.

  • Wind power cable
    More...

    Range of application

    To fan the cabin: soft wire, control cable, cable, cable drag chain (used in the rotor circuit is composed), etc.

    The fan inside the tower: cloth wire (lighting), power cable (fixed installation and the reverse)

    Execution standard

    HD22.1 / HD22.4, UL44, UL62.

    Technical characteristics

    Products with resistance to ultraviolet radiation, ozone resistance, weatherability, damp heat, low temperature resistance, flame retardant performance, torsion resistance, oil resistance, corrosion resistance, salt fog, sea water).

     

  • Medium voltage cable
    More...

    Range of application

    This product is suitable for fixed installation in ac 50 hz, rated voltage 3.6/6 kv ~ 26/35 kv power transmission and distribution lines for transmission of electricity.

    Execution standard

    GB/T 12706.2 2008 "rated voltage 1 kV (Um = 1.2 kV) to 35 kV (Um = 40.5 kV) insulated power cables and accessories

    Part 2:6 kV rated voltage (Um = 7.2 kV) to 30 kV (Um = 36 kV cable "GB/T12706.3-2008" rated voltage 1 kV (Um = 1.2 kV) to 35 kV (Um = 40.5 kV) insulated power cables and accessories

    Part 3:35 kV rated voltage (Um = 40.5 kV cable standard.

    Technical characteristics

    Rated voltage 3.6/6 kv ~ 26/35 kv cable; Cable conductor allows maximum working temperature of 90 ℃ for a long time; When a short circuit (the longest duration of no more than 5 s) cable conductor does not exceed the highest temperature of 250 ℃. Cable when the ambient temperature under installation should not below 0 ℃, the minimum bending diameter should not less than the following provisions: single core cable minimum bending diameter should not less than 20 d (mm), multi-core cable minimum bending diameter should not less than 15 d (mm).

  • Low voltage cable
    More...

    Range of application

    This product is suitable for fixed installation in ac 50 hz, rated voltage up to and including 0.6/1 kv power transmission and distribution lines for transmission of electricity.

    Execution standard

    GB/T12706.1-2008 "rated voltage 1 kV (Um = 1.2 kV) to 35 kV (Um = 40.5 kV) insulated power cables and accessories

    Part 1: rated voltage 1 kV (Um = 1.2 kV) to 3 kV (Um = 3.6 kV cable"

    Technical characteristics

    The highest rated cable conductor temperature is 90 ℃; When a short circuit (the longest duration of no more than 5 s) cable conductor does not exceed the highest temperature of 250 ℃. Cable when the ambient temperature under installation should not below 0 ℃, the minimum bending diameter should not less than the following provisions: single core cable minimum bending diameter should not less than 20 d (mm), multi-core cable minimum bending diameter should not less than 15 d (mm).